Dual 4-to-1 Multiplexer with Active-Low Enables and Common Select Input
When the active-Low enable inputs G1 and G2 are Low, the data output Y1, reflects the data input chosen by select inputs A and B from data inputs I1C3 – I1C0. The data output Y2 reflects the data input chosen by select inputs A and B from data inputs I2C3 – I2C0. When G1 or G2 is High, the corresponding output, Y1 or Y2 respectively, is Low.
Parameters
Parameter | Description | Units | Default |
---|---|---|---|
DELAY | Propagation delay. | s | DGTDELAY |
IN_MODE | Inputs mode. | IN | |
OUT_MODE | Outputs mode. | OUT | |
IOMODEL | The name of an I/O model, which describes the device’s loading and driving characteristics. | DGTDEFIOMODEL | |
POWER_NODE | Digital power node name. Is the node used by the interface subcircuits which connect analog nodes to digital nodes. | $G_DPWR | |
GROUND_NODE | Digital ground node name. Is the node used by the interface subcircuits which connect analog nodes to digital nodes. | $G_DGND |