This component simulates the operation of a garage door control system.
Ports
Pin |
Description |
COM |
Common terminal. Connected to the ground. |
FLASH |
A positive voltage, greater than or equal to 5 volts, on this terminal causes the lamp to flash. |
CLOSE |
A positive voltage, greater than or equal to 5 volts, on this terminal activates the motor for closing the door. |
OPEN |
A positive voltage, greater than or equal to 5 volts, on this terminal activates the motor for opening the door. |
OPENED |
End of stroke in opening. This terminal is connected to the COM terminal by a resistor.
The resistance value is RESON when the door is completely open otherwise the resistance value is RESOFF. |
CLOSED |
End of stroke in closing. This terminal is connected to the COM terminal by a resistor.
The resistance value is RESON when the door is completely closed, otherwise the resistance value is RESOFF. |
DANGER |
Output of the infrared (IR) beam detector. This terminal is connected to the COM terminal by a resistor.
The resistance value is RESON when the IR beam is broken otherwise the resistance value is RESOFF. |
Parameters
Parameter |
Description |
Units |
Default |
RESON |
On resistance. |
Ohms |
1mΩ |
RESOFF |
Off resistance. |
Ohms |
1GΩ |
WORKTIME |
Time for opening. In seconds. The value is referred to the real time and not to the simulation time. |
s |