Use this source to create a single frequency, frequency modulated waveform.

Parameters

Parameter Description Units Default
DC DC Amplitude of the source used in operating point analysis. V or A 0
VO DC offset voltage or current. Used to adjust the DC bias of the signal generator with respect to the negative terminal (usually ground). V o A  
VA Peak amplitude. V o A  
FC Carrier frequency. Hz  
MDI Modulation index. Value corresponding to a function of amplitude of the modulating signal indicating the level of modulation. MDI=(frequency deviation)/FS.    
FS Signal frequency. Hz
PHASEC Carrier phase. degree  
PHASES Signal phase. degree  
ACMAG AC Magnitude of small signal voltage or current. Set this if you plan to do a small signal AC analysis based on this source. V or A  
ACPHASE AC Phase of small signal voltage or current. Set this if you plan to do a small signal AC analysis based on this source. If phase is omitted, a value of zero is assumed. degrees  
DISTOF1 Set this if you plan to do a distortion analysis based on this source. Specify the amplitude and phase using space as separator. If phase is omitted, a value of zero is assumed.    
DISTOF2 Set this if you plan to do a distortion analysis based on this source. Specify the amplitude and phase using space as separator. If phase is omitted, a value of zero is assumed.