The subcircuit transformer model supports magnetization and leakage inductance.
Parameters
| Parameter | Description | Default |
|---|---|---|
| Ratio | Secondary turns/primary turns | 1 |
| RP | Resistance of primary winding | 0.1 ohms |
| RS | Resistance of secondary winding | 0.1 ohms |
| Leak | Leakage inductance | 1 µH |
| Mag | Magnetizing inductance | 1 µH |
See also
Inductive Coupling
Magnetic Core
XSpice Transformer
Coupled Inductors